Success Story

Client: Jameco Electronics

Location: Belmont, CA

Project Type: Commercial

Existing Roof Top Conditions

  • 48,648 SF Tar & Gravel Roof
  • 30 years old
  • Asphalt on roof was aged and exceeded its life expectancy
  • Existing ponding water and poor drainage


Existing Building Conditions

  • High energy consumption
  • Minimal natural light entering building through windows
  • Out of date HVAC units
  • Inefficient interior lighting

Clients Preferences

  • Reduce energy consumption of entire building envelope
  • Install a new roof with a long term warranty and durability

Challenges

  • Not interrupting daily building operations
  • Coordinating roof, HVAC and lighting work so all phases are completed on schedule and without interruptions

Dinyari Solutions

  • Install light weight EPS to raise low spots
  • Install 2” of Poly ISO, bring roofing system from a R7 to a R15
  • Overlay the Poly ISO with Carlisle 60mil TPO Spectro membrane
  • Replaced existing HVAC units with new high efficiency units (went from SEER 7 to 15.9)
  • Seal and coat roof top ductwork with CeramaFlex to eliminate water intrusion and reduce HVAC load in the summer months.
  • Install 160 new SunOptic Prismatic skylights with curbs and safety screens
  • Install all new prefabricated drains
  • Conduct a full interior lighting retrofit
  • Not interrupting daily building operations
  • Coordinating roof, HVAC and lighting work so all phases are completed on schedule and without interruptions

Success

  • Reduced lighting energy consumption by 60%
  • Reduced entire building envelope consumption by 50%
  • HVAC systems were down sized by 30%
  • Created a more pleasant work environment for Jameco employees by adding more natural light through the installation of skylights
  • Jameco’s daily operations were never compromised and there was no loss in productivity
  • Dinyari didn’t miss one day of schedule work and entire project was complete on schedule and on budget
  • Carlisle TPO Spectro “cool roof” membrane reduces the heat island effect due it is superior reflectivity and emissivity.
  • Addition of 2” Poly ISO will help minimize heat transfer to and from the building and keep it warmer in the winter and cooler in the summer, reducing the need for AC and HVAC units
  • New total roofing system comes with a 20-Year NDL Labor & Material Warranty backed by Carlisle Syn-Tec
  • Title 24 & LEED Compliant and Energy Star Approved
  • Jameco is eligible for thousands of dollars in federal and utility rebates due to these upgrades

Click here to view George’s testimonial from Jameco >>